1. Reated Voltage: 300V
2. Rated Temperature: 90°C/105°C
3. Passed UL VW-1 & CSA FT2 Flame test.
4. Bare or tinned stranded copper conductor.
5. Insulating Material: CPE or CSM
6. EP for ground wires' insulating material.
General data for cable bype HPN
Type |
Conductor |
Insulation |
Green Grounding Cond |
Overall Diam (mm) |
Max.Cond.Resist Ohm/km/20°C | ||
Size |
Construction (No./mm) |
Nom. Thick (mm) |
Nom. Thick (mm) |
Nom. Thick (mm) | |||
HPN |
16AWG/2C |
65/0.16 |
1.14 |
0.38 |
0.33 |
3.9±0.05×7.6±0.15 |
13.5 |
18AWG/2C |
41/0.16 |
1.14 |
3.5±0.05×6.9±0.10 |
21.4 | |||
16AWG/3C |
65/0.16 |
1.14 |
3.9±0.10×10±0.15 |
16.9 | |||
18AWG/3C |
41/0.16 |
1.14 |
3.8±0.10×79.0±0.15 |
21.4 | |||
17AWG/2C |
52/0.16 |
1.14 |
3.7±0.05×7.2±0.10 |
16.9 | |||
14AWG/2C |
41/0.254 |
2.03 |
5.1±0.15×9.1±0.25 |
8.45 | |||
14AWG/3C |
41/0.254 |
2.03 |
5.1±0.20×11.3±0.30 |
8.45 |
This kind of HPN-R power cord is a brand star products of our company, we accquired the UL/CUL & CSA certificate on this cord. It can completely compliance with the new requirement of UL for power supply cord on heater.(Abrasion test;Mandrel pitching tet;Mandrel crushing test;Flexing test.